EBP EBP-R Floor grilles

Description

Floor grilles composed by horizontal fixed bars with 12,5 mm pitch.

Characteristics

Material: aluminium.
Finish grille: anodized aluminium.
Regulation damper material: galvanized steel.

Use

Air supply and extraction both in heating and cooling mode.

Accessories

- SCPT calibration damper in galvanized steel with fins with opposing movement.

Model

- EBP floor grate with horizontal threaded bars;
- EBP-R floor grating with horizontal threaded bars adjustable in height from 30 to 45 mm;
- EBP + SCPT floor grate with horizontal threaded bars with regulation damper;
- EBP-R + SCPT floor grating with horizontal threaded bars adjustable in height from 30 to 45 mm with regulation damper.

EBP - EBP with SCPT damper

EBP + SCPT dimensions

EBP-R - EBP-R with SCPT damper

EBP-R + SCPT dimensions

NOTE FOR FLOATING FLOORS

There is no unification of floating floors, SO the use of 600x600mm grids within these floors is normally only possible in without frame version, with fixed or adjustable height.If the calibration damper is required, the measure compatible with most floating pavements is 525x525mm. It is however recommended that you communicate the floating floor features of your use in order to identify the most suitable solution for your case

EBP operating data in supply air

Vk: effective speed (m/s)
m³/h: air flow
Pa: pressure drop in Pascal
L(m): air throw in meters calculated with terminal velocity 0.25 m/s
dB(A): noise level

Dimensions are expressed in mm.



 
Dimension LxH effective section   Air flow m3/h
H = 100 mm   100 150 200 250 300 350 400 500 600
300x100 0,0100 dB(A) <20 29 37 43 48        
Vk (m/s) 2,8 4,2 5,6 6,9 8,3        
Pa 6 14 25 37 54        
L (m) 2,6 3,9 5,2 6,5 7,8        
400x100 0,0135 dB(A) <20 21 29 35 41 45 49    
Vk (m/s) 2,1 3,1 4,1 5,1 6,1 7,2 8,2    
Pa 3 8 13 20 29 40 53    
L (m) 2,3 3,4 4,5 5,6 6,7 7,8 8,9    
500x100 0,0171 dB(A)   <20 24 30 35 39 43 50  
Vk (m/s)   2,5 3,3 4 4,9 5,7 6,5 8,1  
Pa   5 8 13 18 25 33 52  
L (m)   3 4 4,9 5,9 7 8 10  
600x100 0,0206 dB(A)   <20 <20 25 30 35 39 45 50
Vk (m/s)   2 2,7 3,3 4 4,7 5,4 6,7 8,1
Pa   3 6 9 13 17 23 35 51
L (m)   2,7 3,6 4,5 5,4 6,3 7,2 9,1 10,9

EBP-R height 100 mm are not feasible.

EBP / EBP-R operating data in supply air

Vk: effective speed (m/s)
m³/h: air flow
Pa: pressure drop in Pascal
L(m): air throw in meters calculated with terminal velocity 0.25 m/s
dB(A): noise level

Dimensions are expressed in mm.

 
Dimension LxH effective section   Air flow m3/h
H = 200 mm   200 250 300 350 400 500 600 700 800 900 1000 1250 1500 2000
300x200 0,0268 dB(A) <20 <20 24 29 32 39 44 48            
Vk (m/s) 2,1 2,6 3,1 3,6 4,1 5,2 6,2 7,2            
Pa 3 5 7 10 13 21 30 41            
L (m) 3,2 3,9 4,7 5,5 6,3 7,9 9,5 11,1            
400x200 0,0362 dB(A)   <20 <20 21 25 32 37 41 49 48        
Vk (m/s)   1,9 2,3 2,7 3,1 3,8 4,6 5,4 6,1 6,9        
Pa   3 4 6 7 11 17 22 29 37        
L (m)   3,4 4,1 4,8 5,5 6,8 8,2 9,5 10,9 12,3        
500x200 0,0458 dB(A)     <20 <20 20 26 31 35 39 43 46      
Vk (m/s)     1,8 2,1 2,4 3 3,6 4,2 4,9 5,5 6,1      
Pa     3 4 5 7 10 14 18 23 29      
L (m)     3,6 4,2 4,9 6,1 7,3 8,5 9,7 10,9 12,2      
600x200 0,0554 dB(A)       <20 <20 21 27 31 35 38 41 47    
Vk (m/s)       1,8 2 2,5 3 3,5 4 4,5 5 6,3    
Pa       2 3 5 7 10 13 16 20 31    
L (m)       3,9 4,4 5,5 6,6 7,7 8,8 9,9 11,1 13,8    

 
Dimension LxH effective section   Air flow m3/h
H = 300 mm   300 350 400 500 600 700 800 900 1000 1250 1500 2000 2500
300x300 0,0436 dB(A) <20 <20 21 27 32 37 40 44 47        
Vk (m/s) 1,9 2,2 2,5 3,2 3,8 4,4 5,1 5,7 6,4        
Pa 3 4 5 8 11 15 20 26 32        
L 3,7 4,3 5 6,2 7,5 8,7 10 11,2 12,5        
400x300 0,0590 dB(A)   <20 <20 20 25 29 33 36 39 46      
Vk (m/s)   1,6 1,9 2,4 2,8 3,3 3,8 3,8 4,7 5,9      
Pa   2 3 4 6 8 11 11 17 27      
L   3,7 4,3 5,4 6,4 7,5 8,6 9,6 10,7 13,4      
500x300 0,0745 dB(A)       <20 20 24 28 31 34 40 45    
Vk (m/s)       1,9 2,2 2,6 3 3,4 3,7 4,7 5,6    
Pa       3 4 5 7 9 11 17 24    
L       4,8 5,7 6,7 7,6 8,6 9,5 11,9 14,3    
600x300 0,0902 dB(A)       <20 <20 <20 23 26 29 36 41 49  
Vk (m/s)       1,5 1,9 2,2 2,5 2,8 3,1 3,8 4,6 6,2  
Pa       2 3 4 5 6 7 12 17 30  
L       4,3 5,2 6 6,9 7,8 8,7 10,8 13 17,3  

 
Dimension LxH effective section   Air flow m3/h
H = 400 mm   400 500 600 700 800 900 1000 1250 1500 2000 2500
300x400 0,0604 dB(A) <20 <20 25 29 33 36 39 45 50    
Vk (m/s) 1,8 2,3 2,8 3,2 3,7 4,1 4,6 5,7 6,9    
Pa 3 4 6 8 11 13 17 26 37    
L (m) 4,2 5,3 6,4 7,4 8,5 9,5 10,6 13,2 15,9    
400x400 0,0817 dB(A)   <20 <20 22 25 29 32 38 43    
Vk (m/s)   1,7 2 2,4 2,7 3,1 3,4 4,2 5,1    
Pa   2 3 4 6 7 9 14 20    
L (m)   4,6 5,5 6,4 7,3 8,2 9,1 11,4 13,7    
500x400 0,1032 dB(A)     <20 <20 20 23 26 32 38 46  
Vk (m/s)     1,6 1,9 2,2 2,4 2,7 3,4 4 5,4  
Pa     2 3 4 5 6 9 13 23  
L (m)     4,9 5,7 6,5 7,3 8,1 10,1 12,1 16,2  
600x400 0,1249 dB(A)       <20 <20 <20 22 28 33 41 47
Vk (m/s)       1,6 1,8 2 2,2 2,8 3,3 4,5 5,6
Pa       2 2 3 4 6 9 15 24
L (m)       5,1 5,9 6,6 7,4 9,2 11 14,7 18,4

 
Dimension LxH effective section   Air flow m3/h
H = 500 mm   500 600 700 800 900 1000 1250 1500 2000 2500 3500
300x500 0,0772 dB(A) <20 <20 23 27 30 33 39 44      
Vk 1,8 2,2 2,5 2,9 3,2 3,6 4,5 5,4      
Pa 3 4 5 6 8 10 16 23      
L (m) 4,7 5,6 6,5 7,5 8,4 9,4 11,7 14      
400x500 0,1044 dB(A)   <20 <20 <20 23 26 32 37 45    
Vk   1,6 1,9 2,1 2,4 2,7 3,3 4 5,3    
Pa   2 3 4 4 6 9 12 22    
L (m)   4,8 5,6 6,4 7,2 8,1 10,1 12,1 12,1 16,1  
500x500 0,1319 dB(A)     <20 <20 <20 20 27 32 40 46  
Vk     1,5 1,7 1,9 2,1 2,6 3,2 4,2 5,3  
Pa     2 2 3 3 5 8 14 22  
L (m)     5 5,7 6,4 7,2 8,9 10,7 14,3 17,9  
600x500 0,1597 dB(A)         <20 <20 22 27 35 42  
Vk         1,6 1,7 2,2 2,6 3,5 4,3  
Pa         2 2 4 5 9 15  
L (m)         5,9 6,5 8,1 9,8 13 16,3  

 
Dimension LxH effective section   Air flow m3/h
H = 600 mm   600 700 800 900 1000 1250 1500 2000 2500 3500
300x600 0,0940 dB(A) <20 <20 22 25 28 35 40 48    
Vk 1,8 2,1 2,4 2,7 3 3 4,4 5,9    
Pa 2 3 4 6 7 7 15 27    
L (m) 5,1 5,9 6,8 7,6 8,5 8,5 12,7 17    
400x600 0,1271 dB(A)   <20 <20 <20 21 27 33 41 47  
Vk   1,5 1,7 2 2,2 2,7 3,3 4,4 5,5  
Pa   2 2 3 4 6 8 15 23  
L (m)   5,1 5,8 6,6 7,3 9,1 10,9 14,6 18,2  
500x600 0,1606 dB(A)       <20 <20 22 27 35 41  
Vk       1,6 1,7 2,2 2,6 3,5 4,3  
Pa       2 2 4 5 9 15  
L (m)       5,8 6,5 8,1 9,7 13 16,2  
600x600 0,1944 dB(A)         <20 <20 22 31 37 46
Vk         1,4 1,8 2,1 2,9 3,6 5
Pa         2 2 4 6 10 19
L (m)         5,9 7,4 8,9 11,8 4,7 20,6

Accessories

SC galvanized steel calibration damper SCPT with fins with opposing movement.

Price list

modello bocchetta
EBP
bocchetta
EBP-R
serranda di regolazione
SCPT
LxH euro euro euro
300x100 a.r. - a.r.
400x100 a.r. - a.r.
500x100 a.r. - a.r.
600x100 a.r. - a.r.
300x200 a.r. a.r. a.r.
400x200 a.r. a.r. a.r.
500x200 a.r. a.r. a.r.
600x200 a.r. a.r. a.r.
300x300 a.r. a.r. a.r.
400x300 a.r. a.r. a.r.
500x300 a.r. a.r. a.r.
600x300 a.r. a.r. a.r.
300x400 a.r. a.r. a.r.
400x400 a.r. a.r. a.r.
500x400 a.r. a.r. a.r.
600x400 a.r. a.r. a.r.
300x500 a.r. a.r. a.r.
400x500 a.r. a.r. a.r.
500x500 a.r. a.r. a.r.
600x500 a.r. a.r. a.r.
300x600 a.r. a.r. a.r.
400x600 a.r. a.r. a.r.
500x600 a.r. a.r. a.r.
600x600 a.r. a.r. a.r.