EVBAC - EVBAF Batterie ad acqua per recuperatori serie terziario
Descrizione
Hydronic pre-/post-heating and cooling coil consisting of a galvanized steel frame, copper tubes and aluminum fins.
Structure equipped with male circular air connections with O-ring gasket to facilitate duct installation.
Threaded hydraulic connections complete with air vent and coil drain valves.
Hot Water Coil
Technical Specifications Model EVBAC1 EVBAC2 EVBAC3 EVBAC4 EVBAC5 Airflow 400 700-1000 1500-2000 2500-3500 3500-5000 Attacchi Idraulici 3/4”F 1”M 1”M 1”M 1”M DN
(Ø mm)250 315 355 400 500 H
(mm)240 420 470 570 820 L
(mm)290 440 590 640 640 W
(mm)500 500 500 500 500 Weight (kg) 5 8 11 13 17 Rated Thermal Power1 (kW) 4,18 9,37 19,32 21,46 38,80 Rated Water Flow1 (m³/h) 0,36 0,82 1,69 1,88 3,34 Pressure Drop – Water Side¹ (kPa) 10,80 13,40 21,60 25,90 18,50 Supply Air Temperature¹ (°C) 31,80 34,70 30,00 28,40 29,70 Rated Thermal Power2 (kW) 2,53 5,80 11,92 13,22 23,40 Rated Water Flow2 (m³/h) 0,22 0,50 1,03 1,15 2,00 Pressure Drop – Water Side¹ (kPa) 4,80 6,20 9,90 11,80 8,40 Supply Air Temperature2 (°C) 22,40 24,50 21,60 20,60 21,40 Pressure Drop – Air Side (Pa) 29 21 15 24 17 1Capacities and technical data refer to water inlet temperature 70°C, water outlet temperature 60°C, and inlet air temperature 8°C. 2Capacities and technical data refer to water inlet temperature 50°C, water outlet temperature 40°C, and inlet air temperature 8°C.
Schema
Price List – Hot Water Coil
Chilled Water Coil
Technical Specifications Model EVBAF1 EVBAF2 EVBAF3 EVBAF4 EVBAF5 Airflow 400 700-1000 1000-1500 1500-3000 3000-5000 Hydraulic Connections 1/2”M 1”M 1”M 1”M 1”M D
(mm)250 315 355 400 500 H
(mm)340 490 540 590 890 L
(mm)470 570 780 800 890 W
(mm)450 450 450 450 450 Weight (kg) 6 9 11 16 24 Rated Thermal Power1 (kW) 4,60 10,33 20,84 24,53 41,69 Rated Water Flow1 (m³/h) 0,81 1,80 1,81 2,14 3,63 Pressure Drop – Water Side¹ (kPa) 16,40 20,20 7,00 6,00 7,40 Supply Air Temperature¹ (°C) 34,50 35,10 31,80 31,30 31,70 Sensible Cooling Capacity² (kW) 5,59 12,70 8,19 9,56 16,44 Latent Cooling Capacity 2 (kW) 2,46 5,56 18,71 21,76 37,65 Rated Water Flow2 (m³/h) 0,91 2,20 3,21 3,74 6,46 Pressure Drop – Water Side¹ (kPa) 26,40 29,20 23,00 19,50 24,80 Supply Air Temperature2 (°C) 16,00 15,40 16,79 17,06 16,75 Pressure Drop – Air Side (Pa) 48 59 62 66 63 1Capacities and technical data refer to water inlet temperature 50°C, water outlet temperature 40°C, and inlet air temperature 8°C, 50% RH. 2Capacities and technical data refer to water inlet temperature 7°C, water outlet temperature 12°C, and inlet air temperature 27°C, 70% RH.
Chilled Water Coil Diagram
Price List – Chilled Water Coil