EVHRDS EC Compact unit for controlled mechanical ventilation, dehumidification and air handling systems from 300 to 500 m³/h
Description
The EVHRDS EC is a compact INVERTER-driven unit for Controlled Mechanical Ventilation systems with a dehumidification section and cooling and heating integration. The unit is supplied as a plug-and-play solution for quick and easy installation. The unit consists of a one-piece structure including every component for correct operation with wide temperature ranges.
Characteristics
Painted sheet metal self-supporting perimeter structure. The panels are insulated with 6 mm thick polyethylene. Dual-suction fans with Brushless EC motor. Very high efficiency and low noise levels in accordance with Erp regulations. Coarse filters with low pressure drop easily removable on the recirculation air. Cooling circuit made of brazed copper complete with: high efficiency compressor, filter drier, finned coils, water exchanger, solenoid valves, throttling device, liquid receiver, high pressure switches.
Use
The unit is particularly suitable for residential, commercial or collective residential buildings where dehumidification is required in addition to air exchange due to the presence of radiant systems.
Command electronics
Version K: On-board electrical panel with microprocessor and dedicated control. Fan management, motorised recirculation damper management, timed dirty filter management, recirculation and fresh air management.
Possibility of controlling the unit with these three solutions:
- 1: management via external controls and 0...10vdc signal for air flow rate control from minimum to maximum;
- 2: management via EVCNU remote panel with built-in T/H sensor;
- 3: MODBUS RTU RS 485 communication.
Accessories
- V2-1-EVHRD - 2-Way On/Off Water Valve 1/2";
- V3-1-EVHRD - 3-Way On/Off Water Valve 1/2";
- EVFHRDS - Filter Kit (for Recirculation Versions Only);
- EPIV - Insulated Supply Air Plenum.
Versions DC
Version DC all outside air: unit for the dehumidification of the air coming from the heat recovery unit and for the cooling/heating integration to the radiant air conditioning system.
During summer (compressor on) the unit can operate in 2 modes:
- dehumidification: the unit condenses partially in air and partially in water by means of the plate condenser, obtaining dehumidified air;
-dehumidification + Cooling integration: the unit condenses completely in water, thus obtaining dehumidified and cooled air.
During winter (compressor off), the water coil is supplied with hot water from the heating system and behaves like a fan coil with heat recovery unit.
Models:
- EVHRDS EC 30 H K DC
- EVHRDS EC 50 H K DC
Version DC outside air and recirculation: unit for the dehumidification of the air coming partially from the heat recovery unit and partially from the indoor environment, with cooling/heating integration to the radiant air conditioning system.
During summer (compressor on) the unit can operate in 2 modes:
- dehumidification: the unit condenses partially in air and partially in water by means of the plate condenser, obtaining dehumidified air;
-dehumidification + Cooling integration: the unit condenses completely in water, thus obtaining dehumidified and cooled air.
During winter (compressor off), the water coil is supplied with hot water from the heating system and behaves like a fan coil with heat recovery unit.
- EVHRDS EC 30 H R K DC
- EVHRDS EC 50 H R K DC
General Data
Size Horizontal Configuration EVHRDS EC 30 EVHRDS EC 50 Power Supply V/Ph/Hz 230/1/50 Ingress Protection (IP) rating IP 20 Total Airflow Rate m3/h 300 500 Nominal Outdoor Airflow Rate (R versions with recirculation) m3/h 130 190 Pressure Drop – VMC Side Pa 31 38 Rated Power Consumption of Recirculation Fan kW 0,1 0,1
Versions DC
(1) Outside air temperature 33°C; relative humidity 50%. room temperature 25°C; relative humidity 50%, water temperature 16°C. Nominal air and water flow rates.
(2) Outside air temperature 33°C; relative humidity 50%. room temperature 25°C; relative humidity 50%, water temperature 16°C. Nominal air and water flow rates.
(3) Room temperature 20°C; relative humidity 50%, nominal air flow rate; Water in 35°C.
Version DC EVHRD EC 30 EVHRD EC 50 Net Dehumidification Capacity1 l/24h 56 89 Total Cooling Capacity2 kW 2,6 3,95 Compressor Power Consumption kW 0,69 0,95 Compressor Operating Frequency Hz 55 73 EER 3,75 4,15 Sensible Cooling Capacity kW 1,18 1,69 Delivered Heating Capacity3 kW 0,53 1,15 Water Flow Rate m3/h 0,12 0,18 Pressure Drop Kpa 9 7 Sound Pressure Level Lp at 3 m dB(A) 39,5 40,8 Electrical Supply V/Ph/Hz 230/1/50 Maximum Operating Current Draw A 3,7 5,1 Maximum Operating Power Consumption kW 0,79 1,11 Maximum Current Draw – Components A 6,78 7 Maximum Power Consumption – Components kW 1,49 1,55
Dimensions
Dimensions EVHRDS EC 30 EVHRDS EC 50 Larghezza A mm 690 690 Depth B mm 690 800 Altezza C mm 270 320 Recirculation Air Inlet DN1 (not available in non-recirculation version) mm 160 200 Primary Air Inlet (from ventilation unit) DN2 mm 160 200 Supply Air Outlet (b × h) mm 347x177 518x252 Water Connections – Supply / Return Ø" 1/2” - 1/2” 1/2” - 1/2” Water Connection Diameter Ø mm 12 12 Unit Weight DC kg 43 56 Weight – R DC Version kg 46 57
Supply Plenum Dimensions
All dimensions are expressed in mm.
Models L H P Ø EVHRDS EC 30 347 177 100 1x160 EVHRDS EC 50 518 252 100 2x160
Heat Recovery Units and Accessories Price List - Version K
Models Non-Recirculation Versions Recirculation Version Accessories DC R DC EVCNU - Remote Electronic Controller V2-1-EVHRD - 2-Way 1/2" On/Off Water Valve V3-1-EVHRD - 3-Way 1/2" On/Off Water Valve EVFHRDS – Filter Kit (for Recirculation Versions Only) EPIV – Insulated Supply Air Plenum Eur Eur Eur Eur Eur Eur Eur EVHRDS EC 30 3.799,99 4.174,16 296,66 311,90 363,89 36,94 66,30 EVHRDS EC 50 4.078,35 4.452,52 296,66 311,90 363,89 45,14 101,87