EVCD Fan boxes
Description
Soundproof ventilating boxes, for ventilation or air extraction systems.
Features
Material: structure in aluminium profiles and panels in galvanized sheet.
Fan: in galvanized steel with directly coupled motor.
Anti-vibration joints installed on the outlet mouth.
Use
Outlet and inlet of clean or lightly dusty air. Air flow rates from 1000 to 6800 m³/h and static pressure up to 600 Pa , maximum air temperature 40 °C .
Accessories
- RCS - Single phase electronic regulator;
- INVERTER - Three-phase Inverter;
- T-EVCD - Rain cover;
- C-EVCD - Cap with bird mesh;
- PF-EVCD - External filter holder;
- EFPON - Filter;
- K-EVCD - Foot kit.
On demand
- Panels in AISI 304 steel, simple or sandwich.
- Panels in simple or sandwiched aluminum sheet.
- Execution with IP55 motor.
Dimensions
All measures are in mm.
Model A B H C D E F G mm mm mm mm mm mm mm mm EVCD 7/7 500 500 500 220 250 125 100 180 EVCD 9/7 600 600 600 280 250 175 105 215 EVCD 9/9 600 600 600 280 320 140 105 215 EVCD 10/8 600 600 600 310 285 158 85 205 EVCD 10/10 600 600 600 310 350 125 85 205 EVCD 12/9 750 750 750 360 330 210 156 234 EVCD 12/12 750 750 750 360 420 165 156 234
Technical Features
Model W N° of poles Number of Speeds Power Supply IP motor Sound pressure level at 1,5 m Speed Control Weight kg EVCD 7/7 50 6 1 230V-1F-50Hz 30 52 RCS300 22,5 EVCD 7/7 147 4 1 230V-1F-50Hz 55 57 RCS300 23 EVCD 9/7 420 4 1 230V-1F-50Hz 30 63 RCS900 37 EVCD 9/9 420 4 1 230V-1F-50Hz 30 66 RCS900 37 EVCD 10/8 250 6 1 230V-1F-50Hz 20 63 RCS600 38 EVCD 10/8 550 4 1 230V-1F-50Hz 30 65 RCS900 38 EVCD 10/10 250 6 1 230V-1F-50Hz 20 58 RCS600 38,5 EVCD 10/10 550 4 1 230V-1F-50Hz 30 67 RCS900 38,5 EVCD 12/9 745 6 1 230V-1F-50Hz 20 64 RCS210 57,5 EVCD 12/9 1100* 6 1 400V-3F-50Hz 30 67 INVERTER 58,5 EVCD 12/12 736 6 3 230V-1F-50Hz 20 64 RCS210 (vel. max) 62,5 EVCD 12/12 1100* 6 1 400V-3F-50Hz 30 68 INVERTER 63
Air flow
Pa : pressure drop in Pascal
* Three-phase
You can find the performance curves and the noise spectrum in the technical datasheet available in the “Documentation” section.
Model W N° of poles Number of speeds Static Pressure 50 Pa 100 Pa 150 Pa 200 Pa 250 Pa 300 Pa 350 Pa 400 Pa 450 Pa 500 Pa 550 Pa 600 Pa Flow Rate m3/h EVCD 7/7 50 6 1 1000 500 EVCD 7/7 147 4 1 1500 1480 1400 1280 1000 200 EVCD 9/7 420 4 1 2200 2000 1500 200 EVCD 9/9 420 4 1 2500 2200 1700 800 400 EVCD 10/8 250 6 1 2400 2100 1250 EVCD 10/8 550 4 1 2800 2600 2200 1700 500 100 EVCD 10/10 250 6 1 3000 2200 500 EVCD 10/10 550 4 1 2700 2300 1600 1200 700 EVCD 12/9 745 6 1 4450 3800 2900 EVCD 12/9 1100* 6 1 6000 5700 5300 4200 2550 1600 EVCD 12/12 736 6 3 6000 5500 5000 4400 2700 EVCD 12/12 1100* 6 1 6800 6400 5800 5200 4200 2100
Price List
* three-phase
** filter excluded
Model W N° of poles EVCD Speed Control T-EVCD - Roof protection C-EVCD - Hood with bird mesh PF-EVCD - External filter holder** EFPON - Filter ePM10 50% K-EVCD - Foot Kit for EVCD € € € € € € € EVCD 7/7 50 6 952,83 116,06 58,18 78,48 165,16 a.r. 48,43 EVCD 7/7 147 4 979,05 116,06 58,18 78,48 165,16 a.r. 48,43 EVCD 9/7 420 4 1.304,53 168,48 60,85 83,17 174,82 a.r. 48,43 EVCD 9/9 420 4 1.219,51 168,48 60,85 83,17 174,82 a.r. 48,43 EVCD 10/8 250 6 1.243,91 142,27 60,85 83,17 174,82 a.r. 48,43 EVCD 10/8 550 4 1.250,34 168,48 60,85 83,17 174,82 a.r. 48,43 EVCD 10/10 250 6 1.289,75 142,27 60,85 83,17 174,82 a.r. 48,43 EVCD 10/10 550 4 1.272,92 168,48 60,85 83,17 174,82 a.r. 48,43 EVCD 12/9 745 6 1.819,74 248,98 61,99 85,45 192,95 a.r. 48,43 EVCD 12/9 1100* 6 1.845,89 877,53 61,99 85,45 192,95 a.r. 48,43 EVCD 12/12 736 6 1.780,48 248,98 61,99 85,45 192,95 a.r. 48,43 EVCD 12/12 1100* 6 1.860,15 877,53 61,99 85,45 192,95 a.r. 48,43